Dose Response plot

Aivia Software

Dose Response plot

Dose Response Plot is one of the charting options available in the Charts Panel. It graphs the response of objects by a measurement to different dosages of a drug in a multi-well experiment. The mean/total/min/max measurement value of all objects on a multi-well plate for each drug dosage is represented as a point in the chart.
A dose-response plot can be used to evaluate the potency of a drug for one or more object types, by observing an increase or decrease of the measurement values for increasing drug dosages.

To display the dose response plot, open the Charts Panel and select the Dose Response plot option

from the Charts selection dropdown menu. The chart is only available if the image currently displayed in the viewer is part of a multi-well experiment.

For detailed information about dose response plots in general, please refer to the Wikipedia entry for Dose Response Relationship.

Appearance

When the dose response plot is opened while

  • a multi-well experiment is loaded,

  • a plate is selected in the experiment explorer having at least one condition with at least three condition groups with names that can be interpreted as dosages (i.e. Control, Negative, 0, 0.001, 100, ... without units),

  • an image of a well within the plate is displayed in the viewer, and

  • a multi-well assay was applied producing measurements for one or more object (sub-)sets,

the chart will automatically load an apply group, a measurement, an aggregation type and a condition, and will display:

  • the dosages for the condition on the x-axis, as received from condition group names - by default the dosages are shown in logarithmic scaling - herein, "Control" and "Negative" will be interpreted as 0.

  • the response by the selected measurement on the y-axis

  • a collapse-/expandable legend depicting all object (sub-)sets possessing the measurement

  • points representing the measurement values, aggregated by the aggregation type across all wells of the selected plate that have the condition for the different dosages, colored by the color of their respective object set/subset.

General usage

Select apply group/measurements/aggregation type/condition

To change the apply group/measurement/aggregation type/condition, use the selection box in the upper left of the chart or for the measurement use the arrows left of the y-axis label.

Un-/Select object (sub-)sets

To remove an object (sub-)set from being displayed in the chart, unselect it from the legend. To show an object (sub-)set, re-select it.

Context menu options

You can bring up the context menu by right-clicking anywhere in the Charts Panel. The context menu is specific to the dose-response plot and can be used to adjust chart display options.

 

Name

Description

Name

Description

X-axis scaling

Enables changing the x-axis (dosage) scaling between logarithmic (default) and linear.

Normalization

Enables normalizing all measurement values of each object (sub-)set, by

  • dividing by the maximum measurement value of that object (sub-)set → values will be between the minimum measurement value of that object (sub-)set divided by its maximum and 1,

  • subtracting the minimum measurement value of that object (sub-)set, before dividing by the maximum measurement value of that object (sub-)set → values will be between 0 and 1.

Fitting type

Enables fitting measurement values of each object (sub-)set individually, by

  • Michaelis-Menten: 

    , where Rmin is the minimum measurement value, Rmax is the maximum measurement value, S is the dosage, EC50 is the dosage where the response reaches half of the maximum - also called Michaelis-Menten constant or affinity, for more details see Michaelis-Menten equation,

  • Hill: 

    , where the only difference compared to the Michaelis-Menten equation is the Hill-coefficient Hill - an indicator for cooperativity of the response: Hill < 1 negative cooperative binding, Hill > 1 positive cooperative binding, Hill = 1 non-cooperative. For more details see Hill equation.

The right fit

To select the right fit, evaluate whether cooperativity of the response of the biological system is possible. Independent of the relevance of cooperativity, the Hill equation will always deliver the same or a better fit than the Michaelis-Menten equation - because it is mostly the same equation just with one more parameter - and therefore may seem like the better choice, but for many biological systems cooperativity doesn't make sense and should therefore not be used.


After selecting a fitting method, points in the chart will be fitted using the selected equation using a Levenberg-Marquardt algorithm. The fitting lines for each object (sub-)set will be shown in the plot, including the results for EC50, Hill and the R2-value, where the latter is an indicator for the "goodness" of the fit. If the R2-value is below 0.1 the fit is deemed "unsuccessful" and neither the fitting-line nor the values will be shown.

 

Dose response plot, showing the selection box for apply group, measurement and condition in the upper left corner, legend for displayed object (sub-)sets on the right, two dose (dosage of "Doxorubicin") response (as measured by the measurement "Subset Count/Total Ratio") relationships for "Live (Cytoplasm)" (green points) and "Dead (Cytoplasm)" (red points), both fitted by Michaelis-Menten equation (green and red line), resulting in an EC50-value of 0.000963 and an R2-value of 0.96.

 

 

 

 

 

 

How to use

Example use case: Live-dead assay

The goal of this assay is to measure the concentration-dependecy of drugs for cell-survivability. For this a multi-well experiment is performed with cells on a multi-well plate. The cells express fluorescent markers showing whether they are vital (green) or dead (red) (see example picture on the right). To the wells, drugs (including one "Control"-drug - i.e. cell medium) in increasing dosages is applied (see concept drawing on the right). After recording images from each well, within Aivia the dosages are filled in as condition group names in the Experiment Explorer/Conditions (picture on the right) and afterwards an assay is applied in Assay Appy in the Experiment Explorer to detect the cells (i.e. by Segment by Example) and to classify them as Live and Dead object subsets.

Steps to evaluate the concentration-dependecy of the drugs for cell-survivability:

  1. Open the dose response plot in the charts panel
    The apply group, a default measurement, aggregation type and condition will be selected, all available object (sub-)sets for the measurement will be shown.

  2. Select "Subset Count/Total Ratio" as measurement
    This measurement does not have a mean/min/max aggregation type and will always be shown as total. The chart will show points for all available object (sub-)sets. If there are other object (sub-)sets than "Live" and "Dead" which are not relevant for evaluating cell-survivability, deselect them from the legend on the right.

  3. Select different Drug(s) as condition
    Observe the influence of drugs on cell motility by regarding Subset Count/Total Ratio for "Dead" cells increase for increasing drug dosages, while the Subset Count/Total Ratio for "Live" cells decreases (see picture on the right).

  4. Fit points with Michaels-Menten equation
    If any of the R2-values is very low, the fit is not to be trusted. Otherwise, the fits will yield EC50 values. The lower this value the more potent the drug is for cell-mortality.

Example use case: Receptor-ligand binding assay

The goal of this assay is to measure the receptor-ligand binding affinity for intracellular receptors and membrane-permeable ligands for example by either having a FRET-pair expressed at the receptor changing FRET-efficiency upon ligand-binding or having a fluorescently labelled ligand, in- or decreasing fluorescence upon binding. For this a multi-well experiment is performed with cells expressing the receptor on a multi-well plate. To the wells, the ligand is added in increasing dosages. After recording images from each well, within Aivia the dosages are filled in as condition group names in the Experiment Explorer/Conditions and afterwards an assay is applied in Assay Appy in the Experiment Explorer to detect cells and measure their intensity (of the FRET-pair or of the fluorescently labelled ligand).

Steps to evaluate the receptor ligand binding affinity:

  1. Open the dose response plot in the charts panel
    The apply group, a default measurement, aggregation type and condition will be selected, all available object (sub-)sets for the measurement will be shown.

  2. Select "Mean Intensity" of the channel showing FRET-efficiency or ligand binding in-/decrease as measurement and "Mean" as aggregation type
    The chart will show points for all available object (sub-)sets. If there are more than the "Cells" object set, deselect them from the legend on the right.

  3. Observe ligand binding
    by regarding the "Intensity" values in-/decrease for increasing ligand dosages.

  4. Depending on the actual values, it might be helpful to normalize the intensity values, especially since minimum and maximum of intensity don't necessarily have a direct connection to the minimum or maximum of ligand binding. So, if the binding curve seems to saturate at low dosages and high dosages, normalizing by "Subtracting the minimum and dividing by maximum" will result in a plot going from 0 to 1 and might improve readability of the chart. (see pictures on the right)

  5. Fit points with Hill equation if cooperative binding is expected or Michaels-Menten equation if not
    If any of the R2-values is very low, the fit is not to be trusted. Otherwise, the fits will yield EC50 values. If cooperativity is present and the Hill equation is used the Hill-coefficient is a measure for how cooperative or un-cooperative ligand-binding is.

General advice

Advice for best practices:

Drug dosages

For a reliable EC50-value-evaluation by fitting the dose response curve, it is advisable to use at least one concentration at around the expected EC50-value, one each at around EC10 and EC90 (the concentration where 10 % or 90 % of the response is reached) and down to at least 1/100 * EC50 and up to at least 100 * EC50. Furthermore, since dosages are most commonly plotted on a logarithmic scaling, use dosages to evenly cover the dosage range, i.e. 0, 0.001, 0.003, 0.01, 0.03, 0.1, 0.3, 1, 3, 10, 30.

Normalization

Normalizing the result is a good option if:

  • the values of the measurement used to show the response do not have a real meaning for the response (i.e. Intensity for ligand binding assay, in contrast to Subset Count/Total Ratio for live-dead assay, where the value is the fraction of live or dead cells)

  • the values saturate at the lower range of dosages as well as on the upper range

Cooperativity

Since using the Hill equation will likely result in a better fit than the Michaelis-Menten equation, but cooperativity is less common for biological systems, reconsider cooperativity before applying the "wrong" equation.

Fluorescence microscopy image showing cells stained with fluorescent markers to show vital cells (green) and dead (red).

Left: Depiction of a multi-well plate with six different drugs (Drug 1 as control medium) applied in increasing concentrations.
Right: Dosages as condition groups in Experiment Explorer, for different drugs.

 

Dose response plots for two different drugs ("Drug 1" (control), left and "Drug 2", right) with Subset Count/Total Ratio as response for "Live" and "Dead" cells.

 

Dose response plots for cooperative ligand-binding measured by intensity increase, before normalization (left) and after normalization by "Subtracting minimum and dividing by maximum" followed by fitting by Hill equation (right).